Wire Brake Tool #450-17 Instructions

  1. Remove the neck and consumables (not shown in the diagram).
  2. Remove (unthread) the Wire Brake Pushing Unit.
  3. Using the Wire Brake Tool, slide the Wire Guide Holder out of the connector cone assembly.
  4. Clean any debris or residue on the Wire Guide Holder.

To Reassemble the Wire Guide Holder

  1. Using the Wire Brake Tool, slide the Wire Guide Holder back inside the connector cone.
  2. Replace the Wire Brake Pushing Unit.
  3. Ensure the air tube is attached.
  4. Replace the neck and consumables (not shown in the diagram).
How To Maintain Your TOUGH GUN Robotic Air-Cooled MIG Gun Equipped with Wire Brake
ItemMIG GunsDescriptionPart Number
1TOUGH GUN® 500 amp Air-Cooled Robotic MIG Gun (Wire Brake on TOP)Wire Brake Pushing Unit499
TOUGH GUN 500 amp Air-Cooled Robotic MIG Gun (Wire Brake on BOTTOM)Wire Brake Pushing Unit599
TOUGH GUN ThruArm® Series (5800)Wire Brake Pushing Unit499
TOUGH GUN G2 Series (Conventional Air-Cooled MIG Gun)Wire Brake Pushing Unit599
TOUGH GUN Robotic Water-Cooled MIG Gun (600 amp)Wire Brake Pushing Unit599
2For all MIG GunsAir Tube499-9-15
3For all MIG GunsWire Guide Holder
for 0.035″ – 0.045″ Wire
598
3AFor all MIG GunsWire Guide Holder
for 0.052″- 1/16″ Wire
598-116