How To Maintain Your Tregaskiss Robotic Water-Cooled MIG Gun Equipped with Wire Brake

Wire Brake Tool #450-17 Instructions

  1. Remove Wire Brake.
  2. Slide the Wire Guide Holder out of the connector cone assembly.
  3. Clean any debris or residue on the Wire Guide Holder.

To Reassemble the Wire Guide Holder

  1. Line up the Wire Brake Tool with the Wire Guide Holder as shown in the diagram.
  2. Slide the Wire Guide Holder back inside the connector cone.
  3. Screw in the Wire Brake.
How To Maintain Your TOUGH GUN Robotic Water-Cooled MIG Gun Equipped with Wire Brake

Exploded View and Parts Guide

+ Click to enlarge

How To Maintain Your TOUGH GUN Robotic Water-Cooled MIG Gun Equipped with Wire Brake, IMAGE 2
ItemDescriptionartT Number
1 Nozzle Assembly 451-x-xx
1A Nozzle Assembly 401-x-xx
2Heavy Duty Contact Tip403-1-xx
2A TOUGH LOCK® Heavy Duty Contact Tip 403-20-xx
3Water Cooled Retaining Head Assembly454-1
3ATOUGH LOCK Water-Cooled Retaining Head Assembly 404-30
4Water-Cooled Neck Assembly 495-xx
4A TOUGH LOCK Water-Cooled Neck Assembly 494-xx
5 Wire Brake Assembly (see chart below) WB-xxx
5A Wire Brake499
5BWire Guide HolderSee Below Chart
6Front House Assembly497
7 Blue Water Line 656-15
8Conduit Lube657-15
9Power Cable Assembly659-xx
10 Water-Cooled Outer Jacket 663-1-15
11Water Line Universal Adaptor Assembly664-400
12Power Pin Insulator664-6
13Handle Assembly 666-10
14Rear Housing Assembly416-15
15Power Pin Quick-Connect 214
16Liner Assembly 415-xx-xx
17Water Line (OUT) – 20″ Long (Blue)658-1
18 Water Line (IN) – 20″ Long (Red) 658
19Oetiker Clamp (9.5 mm)656-1
20Wire Brake Tool450-17
21Oetiker Clamp (11.3 mm) 413-5
22Air Tube 499-9-15
23 Jump Liner (see chart below)495-18-xxx
24 Gun Mount for Wire Brake AS-49-00-XW
25 Power Pin Insulator414-400-30

Part Number Chart for Items 5, 5B, and 23

Item 5Item 5BItem 23Wire Size
WB-100 498495-18-35 0.045″
WB-110 498-116 495-18-116 0.052″ – 1/16″

Back to top

INS028 REV 11/05