How to Install or Replace a Neck on a TOUGH GUN G1 Series Robotic Air-Cooled MIG Gun

NOTE: There is a protective ring that must be rotated to expose the neck set screw.
 

Step 1:

How to Install or Replace a Neck on a TOUGH GUN G1 Series Robotic Air-Cooled MIG Gun, STEP 1
  • Using a 5 mm Allen wrench, loosen the screw 1/4 turn to remove the neck.
  • Pull the neck directly out of the connector cone assembly.

Step 2: 

How to Install or Replace a Neck on a TOUGH GUN G1 Series Robotic Air-Cooled MIG Gun, STEP 2
  • Insert the replacement neck into the gun housing, ensuring the key on the neck is lined up with the keyway.
  • NOTE: If the face of the body on the neck cannot be pushed flush to the gun housing, check the seating of the liner in the retaining head.
  • Tighten the set screw (max. 60 in.-lbs. or 7Nm).