Products
Documentation
Articles

SDS Information

SDS Information SDS information for Tregaskiss® TOUGH GARD® anti-spatter liquid is available for download in PDF format in the following languages:

read more...

Gun Series Compatibility with Consumables and Liners

Compatibility Charts Consult the charts below to understand front-end consumable and welding liner compatibility for your Bernard MIG welding gun.  Gun Series Compatibility with Front-End Consumables Systems >> Download the chart in PDF format CK = Conversion kit requiredSP = Special parts required Gun Series Compatibility with Liners >> Download the chart in PDF format  […]

read more...

FAQs | BTB MIG Guns

FAQs | BTB Semi-Automatic Air-Cooled MIG Guns Frequently Asked Questions About the New Bernard BTB Semi-Automatic Air-Cooled MIG Gun Platform Français Bernard has compiled a list of frequently asked questions about the new BTB semi-automatic air-cooled MIG gun platform: Why are you launching the Bernard® BTB semi-automatic air-cooled MIG gun platform? How is it now […]

read more...

FAQ | Pour grands pistolets MIG robotique TOUGH GUN CA3 seulement

FAQ | Pour grands pistolets MIG robotique TOUGH GUN CA3 seulement Foire aux questions sur la conversion au pistolet MIG TOUGH GUN CA3 à partir du pistolet MIG de grande taille English Vendus entre le 31 octobre 2014 et le 7 avril 2015 Tregaskiss a compilé une liste de questions fréquemment posées sur la conversion […]

read more...

FAQ | Pour les de pistolets MIG TOUGH GUN G1 et G2

FAQ | Pour les de pistolets MIG TOUGH GUN G1 et G2 Foire aux questions sur la conversion des pistolets MIG TOUGH GUN séries G1 et G2 en pistolets MIG robotiques à refroidissement par air TOUGH GUN CA3 et TA3 English Tregaskiss a compilé une liste de questions fréquemment posées sur les nouveaux pistolets MIG […]

read more...

FAQ | Pour la plateforme BTB

FAQ | Pour la plateforme BTB Questions fréquemment posées sur la plateforme de pistolet MIG semi-automatique refroidi par air BTB English Bernard a compilé une liste de questions fréquemment posées sur la nouvelle plateforme de pistolet MIG semi-automatique refroidi par air BTB : Pourquoi lancez-vous la plateforme BTB des pistolets MIG semi-automatiques à refroidissement par […]

read more...

FAQ | Pistolet MIG robotise TOUGH GUN CA3 et TA3

FAQ | Pistolet MIG robotise TOUGH GUN CA3 et TA3 English Tregaskiss a compilé une liste de questions fréquemment posées sur les nouveaux pistolets MIG robotiques à refroidissement par air TOUGH GUN® CA3 et TOUGH GUN TA3 et comment convertir les pistolets MIG robotiques à refroidissement par air des séries TOUGH GUN G1 et / […]

read more...

FAQs | TOUGH GUN CA3 and TA3 Robotic Air-Cooled MIG Guns

FAQs | TOUGH GUN CA3 and TA3 Robotic Air-Cooled MIG Guns Frequently Asked Questions About the New TOUGH GUN CA3 and TA3 MIG Guns and How To Convert From TOUGH GUN G1 and G2 Series Français Tregaskiss has compiled a list of frequently asked questions about the new TOUGH GUN® CA3 and TOUGH GUN TA3 […]

read more...

FAQs | TOUGH LOCK Dual Taper Technology

FAQs | TOUGH LOCK Dual Taper Technology Frequently Asked Questions About Dual Taper Technology on TOUGH LOCK Retaining Heads Tregaskiss has compiled a list of frequently asked questions about dual taper technology on TOUGH LOCK® retaining heads: Are the TOUGH LOCK retaining heads backwards compatible with older MIG guns? Will TOUGH LOCK retaining heads with dual […]

read more...

Archive – Q-Gun Backend Upgrade 2005

Diagram 33 showing the old back end of a Q-Gun Diagram 33 showing the old back end of a Q-Gun

Q-Gun MIG Gun Backend Upgrade Effective June 27, 2005 In 2005, Q-Gun™ MIG Guns began shipping with upgraded back end assemblies. It is important to know which back end assembly your Q-Gun MIG Gun has when choosing replacement parts. Use the drawings below to determine which back end you have. Old Back End Assembly The […]

read more...

Troubleshooting Guide

Welding Troubleshooting Guide Problem Possible Cause Possible Solution Electrode does not feed or erratic wire feeding. 1. Feeder relay / malfunction. Consult feeder manufacturer. 2. Feeder relay / malfunction. a. Test & connect spare control lead.b. Install new cable.   3. Poor adaptor connection. Test & replace leads and/or contact pins.   4. Worn or broken […]

read more...

FAQs | 600 amp Robotic Water-Cooled Conversion

FAQs | 600 amp Robotic Water-Cooled Conversion Frequently Asked Questions About Converting Your Keyed or Quick-Change Robotic Water-Cooled MIG Gun to the 600 amp Robotic Water-Cooled Model Tregaskiss has compiled a list of frequently asked questions about converting from the keyed or quick-change robotic water-cooled MIG gun to the 600 amp robotic water-cooled model: I think […]

read more...

FAQs | TOUGH GUN I.C.E. Conversion

FAQs | TOUGH GUN I.C.E. Conversion Frequently Asked Questions About Upgrading Your Robotic MIG Gun with TOUGH GUN I.C.E. Technology Tregaskiss has compiled a list of frequently asked questions about upgrading your existing TOUGH GUN® robotic air-cooled MIG gun to a model equipped with TOUGH GUN I.C.E.® technology: I think TOUGH GUN I.C.E. components will […]

read more...

Recommended Operating Tips

Recommended Operating Tips for Robotic Welding Applications Nozzles Contact Tips Retaining Heads Gas Diffusers Liners Necks Gun Cables Reamers Nozzles: If anti-spatter is used, do not use excessive spray times as this will saturate the nozzle insulator and will degrade insulating material. Learn more about TOUGH GARD® anti-spatter liquid from Tregaskiss. Nozzle should be cleaned […]

read more...